Pulsed Xenon Lamp Benchtop Spectrophotometer 3NH YS6080 To Replace Minolta CM3700A Xrite CI7800

Shenzhen ThreeNH Technology Co., Ltd.

Pulsed Xenon Lamp Benchtop Spectrophotometer 3NH YS6080 To Replace Minolta CM3700A Xrite CI7800

Brand Name : 3nh

Model Number : YS6080

Certification : CE, TUV, FCC, ISO9001, RoHS

Place of Origin : Shenzhen China

MOQ : 1 Unit

Price : Please send inquiry

Payment Terms : T/T

Supply Ability : 1000 Unit per Month

Delivery Time : 5-8 Days

Packaging Details : 380*310*210mm, 18KG, Aluminum Box Package

Optical Geometry : d/8 & d/0

Wavelength : 360-780nm

Repeatibility : DeltaE ≤ 0.03

Inter-instrument Error : DeltaE ≤ 0.15

Aperture : 25.4mm & 15mm & 8mm & 4mm

Sphere Size : Φ154mm

Contact Now

3NH YS6080 Pulsed Xenon lamp Benchtop Spectrophotometer to replace Minolta CM3700A and Xrite CI7800

Product Description

Brief Introduce:

YS6080 is a benchtop grating spectrophotometer which is developed by 3nh independently with independent intellectual property. YS6080 has many features, like 7 inches TFT capacitive touch screen display, full illuminants, reflective d/8 and transmissive d/0 geometry (including or excluding UV). With very stable and precise color measurement, large storage and powerful PC software all makes YS6080 ideal for color analysis within R&D and laboratory environments.

Features:

1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Bluetooth 2.1; Concave Grating.

2, Double Array 256 Image Element CMOS Sensor; Long life-span stable xenon lamp.

3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.

4, Auto identify measuring aperture. Freely switchable between 3 measuring apertures: Φ 25.4mm/8mm/4mm. Users also can customize apertures.

5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.

6, Wavelength range 360nm – 780nm. Built-in 400nm/420nm/460nm cut off Xenon lamp, more professional in UV measurement.

7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.

8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.

9, Multiple accessories, sample holders, fixation clamp, suitable to more working condition.

10, Big capacity data storage, for 20000 pieces test result.

11, Built-in camera locating.

12, More powerful extended functions at the PC software.

Application Industry:

YS6080 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical, cosmetics, food, science institutes, laboratories.

Technical Specification;

Model YS6080(Xenon Lamp)
Optical Geometry

Reflectance: d/8 (SCI⪰ Include UV/Exclude UV)

Transmittance: d/0 (SCI⪰ Include UV/Exclude UV)

Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7

Specular Component

Reflectance: SCI&SCE

Transmittance: SCI&SCE

Integrating Sphere Size Φ 154mm
Sensor 256 Image Element Double Array CMOS Image Sensor
Light Source Device 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp,420nm cut-off Xenon Lamp,460nm cut-off Xenon Lamp
Illuminants D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Spectrophotometric Mode Concave Grating
Observer Angle 2° & 10°
Repeatability

Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%)

Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.03 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)

Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.04 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Inter-instrument Error

Φ25.4mm/SCI, Within ΔE*ab 0.12

(Average for 12 BCRA Series II color tiles)

Wavelength Range 360-780nm
Wavelength Pitch 10nm
Semiband Width 10nm
Reflectance Range 0~200%
Measuring Aperture

Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;

Transmissive : Φ30mm/Φ25mm;

Color Space CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy
Color Difference Formula ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99
Displayed Data Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset
Colorimetric Index

WI (ASTM E313, CIE/ISO, AATCC, Hunter),

YI (ASTM D1925, ASTM 313),

TI (ASTM E313, CIE/ISO),

MI (Metamerism Index),

Staining Fastness, Color Fastness, Color Strength, Opacity,

Gardner Index, Pt-Co Index, 555 Index,

PC Terminal Software SQCX
Data Storage Capacity

Standard: 5000 Pcs; Sample: 40000 Pcs.

(One PCS can include both SCI and SCE)

Data Port USB & Bluetooth
Locating Method Camera Locating
Measurement Mode Single Measurement & Average Measurement
Screen 7" TFT Capacitive Screen-touch Display
Light Source Device Life 5 years, more than 3 million times measurements.
Power Supply DC 24V, 2A Power Adapter
Size 370×300×200mm
Weight 16kg
Language English & Chinese
Working Environment Temperature: 0~40℃; Humidity: 0~85% (No Condensation)
Storage Environment Temperature: -20~50℃; Humidity: 0~85% (No Condensation)
Standard Accessory White and Black Calibration Board, Checking Green Board, Sample Holder, Φ4mm, Φ8mm, Φ15mm,Φ25.4mm Aperture, Power Adapter, USB Cable, User Guide, PC Software
Optional Accessory Micro-printer, Transmissive Test Clamp Component

Packaging & Shipping

Package: Alumnium alloy metal box, carton package.

Payment: T/T, Western Union, Paypal

Lead Time:1-3 workdays

Shipping methods: DHL, Fedex, UPS, EMS

Company Information

Shenzhen 3nh Technology Co., Ltd. is a high-tech enterprise, owning 20-year experience in researching, developing, producing and marketing the photoelectric detection products in photoelectric detection technology field and color management field.

Our main product range includes:


-grating spectrophotometer
-spectrophotometer
-colorimeter
-gloss meter
-ISO1233 resolution test chart
-optical image test solution and specific standard illuminants

The spectrophotometer equipments of 3nh conforms to CIE No.15,ISO77241,ASTM E1164,DIN5033 Teil.

Our Certificates: ISO9001:2008; CE; FCC; ROHS; TUV.

Cooperations partners in the long term are as listed:

Domestic: LG, Lenovo, Huawei, Kelon, Youngor, Haier, Media, Galanz, Kelon, Power Dekor

Overseas: Philips, Sony, Simens, Emerson, Colgate, Unilever, Nike, Seiko, YKK

Brand name: 3nh® , Tilo® (trademark)

Contact Information:

Company firms: Shenzhen 3nh Technology Co., Ltd. | Shenzhen Sine Image Technology Co., Ltd. | Shenzhen TILO Technology Co., Ltd. | Shenzhen ThreeNH Technology Co., Ltd.

contact person: Melissa;

email: sales0022 at 3nh.com;

skype: Melissa-3NH;

QQ:1693962918

Website: www.3nh.com | www.sineimage | www.3nhcolorgloss.com
Add:F/6, Block 5B, Skyworth Inno Valley, Tangtou 1st Road,Shiyan, Baoan District, Shenzhen, P.R. China. PC:518000
Your inquiries are highly welcomed by me! Quick response offered within 24 hours.

Pulsed Xenon Lamp Benchtop Spectrophotometer 3NH YS6080 To Replace Minolta CM3700A Xrite CI7800

Pulsed Xenon Lamp Benchtop Spectrophotometer 3NH YS6080 To Replace Minolta CM3700A Xrite CI7800

Attached:

Related knowledge about spectrophotometer

Color Space
CIE LAB
-L(Lightness)-0 is black,100 is white
-a(Red-Green)-positive values are red; negative values are green and 0 is neutral
-b(Blue-Yellow)-positive values are yellow;negative values are blue abd 0 is neutral
CIE LCH
L: Lightness,value is the same in each scale C:Chroma H:Hue Angle
dE Total Color difference
Delta-E is a measurement used to indicate how much a color deviates from an accepted standards.The higher the dE, the more inaccurate the color.

Pulsed Xenon Lamp Benchtop Spectrophotometer 3NH YS6080 To Replace Minolta CM3700A Xrite CI7800

Delta E Meaning
0~1 A normally invisible difference
1~2 Very small difference, only obvious to a trained eye
2~3.5 Medium difference, also obvious to an untrained eye
3.5~5 An obvious difference
>6 A very obvious difference

Product Tags:

colour measurement equipment

      

integrating sphere spectrophotometer

      
Buy cheap Pulsed Xenon Lamp Benchtop Spectrophotometer 3NH YS6080 To Replace Minolta CM3700A Xrite CI7800 product

Pulsed Xenon Lamp Benchtop Spectrophotometer 3NH YS6080 To Replace Minolta CM3700A Xrite CI7800 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen ThreeNH Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)